AC Current Meter – 20 Amp
- Description
- Product Specification
- Documentation
- Applications
Description
Senseit wireless AC Current Meters measure the RMS current of an alternating current (AC) system using a current transformer (CT) that wraps around the “hot” wire of a two wire (hot, common, ground(optional)) power system. The sensor reports Minimum RMS current, maximum RMS current, average RMS current, and amp hours to the iSenseit system. The iSenseit system is capable of generating watt hour or kilowatt hour readings as well.
The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 – 3.6 V power supply (Included with Line Power option upgrade). The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage.
Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements.
WARNING: This AC current meter is for monitoring AC voltage only. Do Not Use with DC voltage.
What does this wireless sensor’s data look like in software?
Product Features
- Measures amp hours, max RMS current, min RMS current, and average RMS current.
- Capable of generating Watt Hour or Kilowatt Hour readings using iSenseit.com.
- Data logging for accumulated amp hour readings.
- Can notify based on current levels or changes in current levels.
- Measures current from 0 – 20 Amps.
What’s in the box?
- Wireless Sensor
- Mounting Hardware
- 2 x AA Batteries
AC Current Meter Specifications
Accuracy | +/- 2% @ 2 to 20 Arms, +/- .07 Arms @ < 2 Arms |
Current Transducer Frequency Range | 50 – 100 Hz |
Absolute Max CT Current | 50 Amps RMS (Arms) |
Maximum Accurate CT Current | 20 Arms |
Calibrated Accuracy with Appropriate Offset | +/- 1% @ 2 to 20 Arms, +/- .035 Arms @ < 2 Arms |
Offset Limits | -1.27 to + 1.27 Arms (default set to +.1 Arms) |
Measurement Resolution | ~.01 Arms |
AA Specifications
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Sensing Element | 2.0 - 3.6 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Device Range | 250 - 300 ft. non-line-of-sight device range* |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 3-4 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
900 MHz Specifications
Operating Frequency | 900 MHz Operating Frequency |
Certifications | Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-RFSC1) Complies with Industry Canada standards. (IC: 9794A-RFSC1) |
- Current Monitoring
- Current Usage
- Amperage Monitoring
- Amp Hour Meter
- Watt Hour Meter
- Kilowatt Hour Meter
Related Products
- Select optionsProduct added! Browse WishlistThe product is already in the wishlist! Browse WishlistQuick View
AC Current Meter – 150 Amp
0 out of 5Select optionsProduct added! Browse WishlistThe product is already in the wishlist! Browse WishlistQuick View